Fix Windows Nt Afa Error (Solved)

Home > Windows Nt > Windows Nt Afa Error

Windows Nt Afa Error

When in doubt, it is best to check with your vendor.†A corrupt Partition Boot Sector can also cause this STOP message, depending upon what part is corrupt. In the case of an x86-based computer, this disk is usually PhysicalDrive0.†3.In the Handle 0 group box, click Set Active. Fdisk refers to the system partition as the active partition. Here, the Last Known Good control set has already been updated to include the changes.†•Switching between different hardware profiles, such as docked and undocked laptops.

In some cases, the damage to the Partition Boot Sector can cause the computer to stop after displaying a blue screen with the message STOP 0x0000007B INACCESSIBLE_BOOT_DEVICE. The cursor will be on Enter choice. In the Partition table index list box, double click the partition number whose Partition Boot Sector you want to read.†3.Click the Go button next to Relative Sector. 4.On the View menu, This means that the cache was not able to resolve the hostname presented in the URL.

Having no disk signature does not necessarily indicate a problem. If you have installed new hardware or new drivers, they could be causing the problem. Other Sources of Information There are several other sources of information for troubleshooting startup and disk problems: •Chapter 8, "General Troubleshooting," contains details about Microsoft's sources for troubleshooting information and contains Note Windows NT Server can run with 12 MB RAM, although it will probably run quite slowly.

No partitions are set active - disk 1 is not startable unless a partition is set active.†2.The FDISK Options screen has several choices. See the section "Using the /sos Switch," presented earlier in this chapter, for a description of the output you see when using this switch. The section titled "Master Boot Record," within Chapter 3, "Disk Management Basics," contains details about the Master Boot Record. Your cache administrator is webmaster.

In addition, changing LBA modes from one scheme to another can cause you to have to recreate the partitions and reformat the disk.†•Some LBA schemes are not compatible with Windows NT. Stop 0x0000007B -- Inaccessible Boot DeviceThis STOP message means that Windows NT is unable to access the Partition Boot Sector or the required information is not found. The computer uses the CMOS checksum to determine if any CMOS values have been changed other than by using the CMOS Setup program. These examples show portions of the Partition Boot Sector that should be the same or contain similar text on all computers.

Volume is Displayed as UnknownIf you have created and formatted a volume with NTFS or FAT, but you can no longer access files on it, and Disk Administrator displays the volume One way that you can tell you have a problem is if you get a black screen instead of the logon message when you restart Windows NT. If the video is still wrong after turning the power off and restarting, check for IRQ and memory conflicts with other cards on your system. You can use the MS-DOS-based utility Fdisk to look at the partition information.

Infection can occur by running an MS-DOS-based program from either a floppy disk or by starting up MS-DOS on a dual-boot computer. http://ncglqy.ydns.eu/Tl-R Hardware ProblemsIf a device fails to initialize during POST, there can be a problem with accessing it. The Available Physical Drives are listed as PhysicalDrivex, where x=0 for the first hard disk. To use this switch, the memory must be contiguous.

Please try the request again. To change the attributes by using the MS-DOS attribute command, enter: attrib -s -h -r ntldr†CMOS ProblemsThe CMOS typically stores information about the following: •Time and date†•Floppy disks†•Video type†•Hard disks†•Memory installed†Each multi(0)disk(0)rdisk(0)partition(1)\winnt=Windows NT Server 4.0 /MAXMEM=12 Chapter 8, "General Troubleshooting," contains more information about troubleshooting memory problems. This is a sample of the kind of information you might see: Detecting System Component . . .

The system returned: (22) Invalid argument The remote host or network may be down. Note There is a Master Boot Record on each hard disk. If your startup problem is because of a problem with information on the hard disk, you might have to remove the disk from the RISC-based computer and install it as a The Knowledge Base also contains information about troubleshooting these kinds of problems.

Problem Occurs After the Boot Loader StartsThis section describes troubleshooting problems that might occur from the time NTLDR starts executing through the time that you successfully log onto Windows NT. Double click the disk that contains the Master Boot Record used to start the computer. Generated Tue, 01 Nov 2016 20:02:16 GMT by s_wx1194 (squid/3.5.20) Host sospeso per abuso Il tuo host è stato sospeso per abuso.
Per maggiori informazioni clicca qui.

If you have the option to shutdown the computer without logging on, do so.

Your cache administrator is webmaster. Then select the Last Known Good configuration. Such support is often built into the system BIOS. Because the Partition Boot Sector contains several fields that are computer-specific, every byte in your Partition Boot Sector will not be identical to the information shown in the examples here.

Many modern disks, however, exceed 1024 cylinders. This problem is usually the result of a user deleting, moving, or renaming a file that is needed for startup. The first step in figuring out what may be causing a problem is to determine whether the problem is occurring before the operating system takes control. This problem is video-and system-BIOS related.

Click OK.†3.Click the filename NTLDR at the root of the C drive. 4.On the File menu, click Properties.†5.In the Attributes box of the General tab, clear the Read Only and Hidden A common cause of this error is a virus. One partition should have an A in the Status column, which indicates it is the (active) system partition.†3.If there is no system partition, or the wrong partition is set as the Otherwise, click NTFS BootSector or FAT BootSector to see a formatted display of the information.

When you install Windows NT, it creates two paths to the Windows NT folder, such as: scsi(0)disk(0)rdisk(0)partition(1)\WINNT="Windows NT Server Version 4.00" scsi(0)disk(0)rdisk(0)partition(1)\WINNT="Windows NT Server Version 4.00 [VGA mode]" /basevideo If you Use this switch if Windows NT does not startup and you think a driver is missing or corrupted. Fdisk displays the message Partition X made active, where X is the partition number you entered.†4.Press ESC to return to the FDISK Options menu, and press ESC again to exit Fdisk. If you can startup Windows NT, which you might be able to do by using your Windows NT startup floppy disk, try using these utilities: •The Windows NT Diagnostics in the

Even if there is no obvious damage, the Partition Boot Sector might not be working correctly. Generated Tue, 01 Nov 2016 20:02:16 GMT by s_wx1194 (squid/3.5.20) ERROR The requested URL could not be retrieved The following error was encountered while trying to retrieve the URL: http://0.0.0.10/ Connection Done reading BIOS date (1/20/1994) Detecting Bus/Adapter Component . . . Therefore, if you are having problems with startup, and think the problems might be related to changes in your configuration, do not log on.

To replace the sector, see "Replacing the Partition Boot Sector," within Chapter 5, "Preparing for and Performing Recovery." Be sure to change the name back to NTLDR so that the Partition Once the pointer to the next volume has been lost, Windows NT can no longer find out where the volumes start. This recovery method is described in "Troubleshooting by Using the Last Known Good Configuration," presented earlier in this chapter. Fdisk displays the following message if there is no system partition on your first hard disk:†WARNING!

There are several utilities that you can use to troubleshoot these kinds of problems. You might also have the wrong partition identified as the system partition. If you suspect this kind of problem, you should contact your technical support personnel for assistance. Problem Occurs Before the Boot Loader StartsThis section describes the problems that might occur between the time you turn your computer on until you see the boot loader screen.

The problem could be one of the following: •There is no system partition on the first hard disk.†•The Master Boot Record is corrupt. •The Partition Boot Sector is corrupt.†•The Boot.ini file Type 2 (Set Active partition). For example, you can configure multiple partitions and install different operating systems on each partition. If you don't get this error message, then the problem is probably a corrupt Partition Boot Sector.